Quick answer: Finish the dosing system you already own. A new reservoir is optional if the solution’s original bottle, pump instructions and installation requirements allow a safe, accessible arrangement.
Copy these sheets by hand or into your notes. The page keeps nothing you type.
Start with placement and identity
Simplicity’s dosing-container setup guide highlights refill access, labeling, tube routing and siphon risk. Its accessory recommendations are not universal instructions for every doser or solution. Use your exact pump and solution manuals to confirm tubing, venting, placement and any valves; do not add a generic check valve by default.
Reuse the original bottle, buy a reservoir, or wait
| Choice | When it makes sense | Must verify |
|---|---|---|
| Original solution bottle | It is identified, in sound condition and the maker allows this dosing arrangement | Intake connection, cap/vent arrangement, stability, liquid level and easy refill or bottle exchange |
| Dedicated dosing container | A documented compatible container solves access, visibility or space problems | Solution/material compatibility, fittings, usable volume and maintenance access |
| No purchase yet | Existing bottle works or compatibility is unknown | Keep a functioning approved setup; settle unknowns before changing it |
A food container, spare tube or clear plastic jug is not automatically compatible with an aquarium additive. Confirm the actual solution and concentration with the relevant manufacturer. Do not transfer chemicals into unmarked household containers or assume all silicone, acrylic and seals tolerate every additive.
Cross-component worksheet
| Connection / requirement | My installed part | Candidate specification | Manual / confirmation |
|---|---|---|---|
| Pump full model and channel | ________________ | ________________ | ________________ |
| Pump-head tube: exact replacement type | ________________ | ________________ | ________________ |
| Supply tubing: material, inside and outside diameter | ________________ | ________________ | ________________ |
| Fitting/barb/rigid intake dimensions | ________________ | ________________ | ________________ |
| Solution name, concentration and compatibility | ________________ | ________________ | ________________ |
| Container cap, vent and intake arrangement | ________________ | ________________ | ________________ |
| Outlet holder and placement requirements | ________________ | ________________ | ________________ |
The tube inside a peristaltic pump head is not necessarily the same specification as the external supply line. A matching nominal diameter alone does not verify material or fitting compatibility. Record each transition so the shopping list names an actual missing part rather than “more tubing.”
Placement sketch to complete
Side view: [container and maximum solution level] → [intake and line route] → [pump] → [fixed outlet over the intended dosing area]. Mark heights and tubing lengths on your own sketch. Simplicity discusses keeping the solution lower than the outlet to avoid siphoning; confirm your entire installation with your pump’s requirements. Do not rely on a pump head or added valve as a universal siphon barrier.
| Cabinet check | Available / measured | Requirement / result |
|---|---|---|
| Footprint with doors closed | ________________ | ________________ |
| Height to lift cap and refill without spills | ________________ | ________________ |
| View of solution level and label | ________________ | ________________ |
| Tube route without sharp bends or snagging | ________________ | ________________ |
| Outlet height relative to maximum solution level | ________________ | ________________ |
Refill plan: an estimate, not a dose recommendation
Enter the usable volume you can safely draw and your existing programmed daily use in the same units. Estimated days = usable volume ÷ daily use. If daily use is zero or unknown, do not calculate a refill date. Recheck after programming changes, and set an inspection before the estimated depletion date. This arithmetic does not establish the correct dose for your reef.
| Channel / solution | Usable volume (mL) | Existing daily use (mL/day) | Inspection / refill date | Label confirmed |
|---|---|---|---|---|
| Channel A | ________________ | ________________ | ________________ | ________________ |
| Channel B | ________________ | ________________ | ________________ | ________________ |
| Channel C | ________________ | ________________ | ________________ | ________________ |
Keep solutions assigned to their labeled channels, follow mixing instructions outside the container when required, and verify calibration after an approved tubing change. The dosing equipment guide and two-part method guide cover separate pump and chemistry decisions. A new pump is not required simply because you need a bottle or line.
The refill math with invented numbers
Say a bottle holds 1,000 mL you can safely draw and the channel is programmed for 25 mL a day. Estimated days = 1,000 ÷ 25 = 40. Put the inspection on day 35, not day 40, because the estimate assumes the programming never changes.
Change the program to 30 mL a day and the same bottle lasts about 33 days (1,000 ÷ 30). That's why the page says to recheck after programming changes. The numbers are made up to show the arithmetic. They aren't a dose.
Frequently asked questions
Do I need a matching-brand reservoir?
Not automatically. Verify the full solution, container, fittings and pump requirements; an approved original-bottle arrangement may be enough.
Should every line have a check valve?
No universal valve prescription applies here. Follow the exact pump and solution instructions, including placement and calibration requirements.
One source, used narrowly
Source checked November 8, 2026: Simplicity Aquatics' dosing-container guide, used only for placement, access, labeling and siphon risk. The worksheets are ours and untested on your pump. Your pump and solution manuals outrank this page.
If you do need a part
The links go to dosing-supply categories, not to a specific container or tubing, and they aren't a stock check. If the original bottle and your current tubing pass the worksheet, buy nothing. If a connection fails, name the missing part from the cross-component sheet before you shop.
Disclosure: Coral Compass may earn a commission when you buy through links on this page, at no extra cost to you. Retailer links are marked as sponsored, and this doesn't change what we recommend. Full disclosure.